TT260 |
|
| |
Features: |
| |
- Two measuring methods: magnetic induction (F) and eddy current (N) Click here for details
- 6 types of probes are available for various applications
- 2 measurement modes: continuous / single
- 5 statistical ways: Mean values / Max. values / Min. values / testing numbers.(No.) / standard deviations (S.DeV)
- Memory up to 495 readings
- Direct testing mode and block statistics mode (APPL/BATCH)
- Direct print out of statistical values
- Dataview for connecting with PC is available
- Low battery indication
- 2 switch off modes: manual and auto
|
| |
 |
| |
6 optional probes available |
| |
Technical Specification |
| |
Measuring range |
Refer to the table below |
Probes available |
Tolerance |
Minimum resolution: |
Measuring condition |
Operation language |
English |
Standards |
DIN, ISO, ASTM,BS |
Calibration |
Zero and foil calibration |
Statistics |
Number of measurements, mean, standard deviation,
maximum and minimum of 3000 readings |
Data memory |
495 readings |
Limits |
Adjustable with alarm |
Interface |
RS-232 |
Working temperature |
0-40℃ |
power supply |
Nicd rechargeable batteries 1.25V |
Dimensions |
270mm×86mm×47mm |
Weight |
Approx. 530g |
|
|
| |
Optional probes and technical specification |
| |
Probe model |
F400 |
F1 |
F1/90º |
F10 |
N1 |
CN02 |
Operating principle |
Magnetic induction |
Eddy current |
Measuring range (µm) |
0-400 |
0-1250 |
0-10000 |
0 to 1250 μm
0 to 40μm (for chromeplate on copper) |
10~200 |
Low range resolution (µm) |
0.1 |
0.1 |
10 |
0.1 |
1 |
Accuracy |
One-point calibration (µm) |
±(3%H+1) |
±(3%H+10) |
±(3%H+1.5) |
±(3%H+1) |
Two-point calibration (µm) |
±[(1~3)H%+0.7] |
±[(1~3)H%+1] |
±[(1~3)%H+10] |
±[(1~3)%H+1.5] |
- |
Measuring conditions |
Min curvature of the min area (mm) |
Convex |
1 |
1.5 |
Flatten |
10 |
3 |
Flatten |
Diameter of the min area (mm) |
φ3 |
φ7 |
φ7 |
φ40 |
φ5 |
φ7 |
Critical thickness of substrate (mm) |
0.2 |
0.5 |
0.5 |
2 |
0.3 |
unlimited |
|
|
| |
Standard delivery |
Optional accessary |
| |
- Main unit
- Calibration foil set
- Substrate
- Charger
- Probe
- Instruction manual
- TIME certificate
- Warranty card
|
- 6 optional probes
- PC software Dataview
- Calibration foils in different thickness
- Connecting cable
|
|
©2007 Copyright |